GretagMacbeth SpectroEye Portable Spectrophotometer (SPE)
Specifications
Download: Product Brochure (pdf) (includes specifications)
Upgrade your SpectroEye
|
SpectroEye combines the ultimate in measurement accuracy with exceptional ergonomics and user-friendliness, setting new standards for color measurement in the graphic arts industry. This handheld, portable spectrophotometer offers all the colorimetric functions needed to accurately measure and control special colors along with all the densitometric functions needed to quickly and easily monitor and control color on press.
The simplest and most accurate method for measuring color and density.
Extendable measuring head for exact positioning and unsurpassed measurement stability.
To ensure optimum measurement accuracy at all times, the white reference tile is integrated, allowing automatic calibration without user intervention.
Innovative track wheel eliminates the need for buttons to push and also allows left or right hand operation.
High resolution graphic display is extremely easy on your eyes.
Easily understandable menus, graphical icons and balloon help guide you step-by-step through the use of the measuring functions.
Menu options can be configured so that each user only sees the information that is relevant and useful.
Optional Best Match function allows you to quickly determine if you can improve the print appearance of an ink by simply changing the ink film thickness, helping to save unnecessary rework.
Optional digital versions of the most popular color guides: PANTONE, HKS, Toyo and DIC allow you to confidently check special colors with ease. In addition, you can store personal libraries containing frequently used references.
Optional Color Quality Software allows you to:
- Store all data for a job in a single place, including references, color standards, tolerances, measurement conditions and any other important order details.
- Trend data, CIELab diagrams, spectral data and statistics, density values and metamerism can be printed in graphic or table form for easy analysis.
- Practical search criteria help access new or existing color data, orders or customer information.
- Pantone® color libraries enable you to directly access the spectral values of Pantone colors reliably and with confidence.
- Utilizes CxF (Color Exchange Format) for seamless digital color communication from design to production to printing
|
|
|
SPECIFICATIONS
|
UPGRADES
|
|
Standard
|
Options
|
|
Measurement Functions
|
|
Colorimetry
|
CIE L*a*b*, CIE L*C*h (a*b*), ∆E* CIELAB
|
CIE XYZ, CIE XyY, CIE L*u*v*, CIE L*C*h(u*v*), ∆E Hunter Lab, RxRyRz
|
|
Special color deviation formulas
|
∆E*2000, ∆E*94, ∆E CMC, ∆E FMCII
|
Metamerism
|
|
Densitometry
|
Density, Dot gain, Dot area, Trapping
|
All densities, Printing plate, Print characteristic, Contrast, Hue error/grayness, Auto function
|
|
Spectrum
|
Reflection spectrum
|
Density spectrum
|
|
Dye strength
|
optional
|
Absolute (K/S) and relative (K/S)
|
|
White- and yellowness
|
optional
|
Whiteness CIE, Whiteness ASTM E313, Whiteness Berger, Whiteness Stensby, ISO Brightness R457, Yellowness ASTM E313, Yellowness ASTM D1925, Tint CIE
|
|
Special functions
|
Best Match
|
|
|
Color guides
|
optional
|
PANTONE® Color Guides TOYO Color Finder; DIC Color Guide; HKS E, K, N and Z
|
|
Security
|
optional
|
Setting protection, Multiuser
|
|
Measurement Conditions
|
|
White base
|
Absolute, relative
|
|
|
Illumination types
|
D50, D65, A, C, D30 ... D300, F1...F12, User defined
|
|
|
Standard observers
|
2º, 10º
|
|
|
Density standards
|
ISO Status A, ISO Status E, ISO Status I, ISO Status T, DIN 16536, DIN 16536 NB, SPI
|
|
|
Measurement Technology
|
|
Spectral analysis
|
Holographic diffraction grating
|
|
|
Spectral range
|
380nm to 730 nm
|
|
|
Physical resolution
|
10 nm (internal resolution: 3.3 nm)
|
|
|
Measurement mode
|
Reflection
|
|
|
Measurement geometry
|
45º/0º ring optic, DIN 5033
|
|
|
Light source
|
Gas-filled tungsten, type A illumination
|
|
|
Physical filters
|
Neutral, incandescent lamp light Polarized Approximated daylight D65 UV cutoff (optional)
|
|
|
Measurement time
|
Approximately 1.5 sec
|
|
|
Measurement range
|
Density DIN 16536: 0.0D-2.5D
|
|
|
Interinstrument agreement
|
Typical 0.3∆E* CIELAB or 0.15∆E CMC (2:1) average based on 12 BCRA tiles (D50, 2º)
|
|
|
Linearity
|
+0.01D
|
|
|
Short-term repeatability
|
0.02∆E* CIELAB (D50, 2º), Mean value of 10 measurements every 10 seconds on white
|
|
|
Density repeatability
|
Density DIN 16536: +0.01D No Filter 0.0D -2,5D, Yellow 0.0D-2.0D Pol Filter 0.0D-2.2D, Yellow 0.0D-1.8D
|
|
|
Measurement head
|
Extendable
|
|
|
Filter wheel
|
Electronic selection of filter
|
|
|
White calibration
|
Automatic on integrated white tile
|
|
|
Instrument check
|
Automatic check of spectral calibration
|
|
|
Density filter recognition
|
Manual and automatic
|
|
|
Average
|
Averaging of multiple measurements
|
|
|
Color detection
|
Manual and automatic assignment of samples to references
|
|
|
Data Interface
|
|
Data interface connector
|
RJ45 connector
|
|
|
Serial data interface
|
RS232C with 300-57,600 baud rate
|
|
|
Ethernet
|
10 Base T, 10 Mbps
|
|
|
Power Supply
|
|
Power supply
|
NiMH battery pack, nom 7.2V, 1300 mAh
|
|
|
AC adapter requirements
|
85-270VAC, 47-63Hz
|
|
|
Charge time
|
Approximately 3 hours
|
|
|
Charge status
|
Automatic capacity checking and display
|
|
|
Measurements per charge
|
Approximately 3000
|
|
|
Size and Weight
|
|
Physical dimensions (length x width x height)
|
24.5 x 8.3 x 8 cm 9.6 x 3.3 x 3.2 in
|
|
|
Weight
|
900 gr (2.2 lb)
|
|
|
|
|
|
|
*Specifications subject to change
|
|